网站标志
加盟留言
版主管理 | 推荐 | 删除 | 删除并扣分
0061 RF Occupancy Or Vacancy Sensor User Guide Lutron Electronics
Refer to that product’s installation sheet for instructions. Twist and remove mounting bracket to insert battery. Product Description Lutron’s ceiling-mounted Occupancy Sensors are wireless, battery-powered, passive infrared (PIR) devices that automatically control lights by way of RF communication with a dimming or switching machine. These Sensors detect the heat from people moving within an space to find out when the house is occupied. The Sensors then transmit the appropriate commands to the related dimming or switching gadget to turn the lights on or off mechanically, providing each comfort and distinctive energy financial savings. Sensor doesn`t carry out satisfactorily from this location, it may be moved to 1.4 Ifanother location by pulling the Sensor straight down and repeating steps 1.Three and 1.4. 1.5 If the Sensor’s performance is passable, it must be permanently hooked up to the ceiling tile, as described in part G. Everlasting Mounting. Momentary Solid Ceiling Mounting Use this procedure if the Sensor can be mounted on a solid, continuous ceiling surface akin to drywall, plaster, concrete, or wooden. Two 3M™ Command™ adhesive strips are offered for temporarily mounting and testing the Sensor on easy, solid ceiling surfaces. These strips are designed for simple, damagefree elimination and usually are not reusable. These strips should not be used for completely mounting the Sensor (see section G. Permanent Mounting ). Rigorously observe the removal instructions under to ensure the ceiling is not damaged throughout elimination. Word: Don`t use the adhesive strips on ceiling tiles, as they`ll possible cause injury to the tile upon removal. Straightforward-to-comply with Instructions Set-Up In order for the Sensor to function correctly, it should first be set up with a corresponding dimming or switching gadget. The process for organising a Sensor with a Maestro Wireless® (MRF2- solely) Dimmer or Digital Swap is detailed below. P/N 041-172a 2.1 Peel the crimson \"Command Strips\" liner off of one of the adhesive strips and apply the strip to the flat side of the mounting bracket as proven in the diagram. Be aware: Do not cover the bracket’s screw holes because they will be used to mark screw gap locations on the ceiling. Setting up a Sensor with a Maestro Wireless Dimmer or Electronic Swap Dimmer Key Features · Low Maintenance. 10-yr battery life. Convenient low-battery indicator. · Multiple Units. Up to three Sensors can work collectively to regulate lights for broader coverage in massive spaces. Every Sensor could also be added to up to 10 receiving devices. Sensor Operation Occupancy Model - The Sensor will robotically flip the lights on when the area is occupied and robotically turn the lights off after the area is vacated. The Sensor will robotically flip the lights off after the house is vacated. There`s a built-in 15-second vacancy grace period that begins when the lights are mechanically turned off, during which the lights will robotically flip back on in response to movement. This grace period is provided as a security and comfort feature in the event that the lights turn off while the room is still occupied, in order that the consumer doesn`t need to manually flip the lights again on. After 15 seconds, the grace interval expires and the lights have to be manually turned on. This Sensor is part of a system and can`t be used to control a load with no appropriate dimming or switching system. Consult with the instruction sheets of the receiving system(s) for installation data. The Sensor may be put in up to 60 ft (18.3 m) away from the related dimming or switching machine(s) if they are in direct line of sight. If there are partitions or different boundaries between the Sensor and receiving gadget(s), the Sensor ought to be positioned inside 30 ft (9.1 m). Warning: This product should not be used to control tools which might create hazardous conditions, corresponding to entrapment, if operated unintentionally. Sensor in a location where it has a broad view exterior the supposed house. If that is unavoidable, the lens may be masked to block the view of undesired areas (check with section I. Lens Masking). This guarantee is in lieu of all different specific warranties, and the implied warranty of merchantability is proscribed to at least one yr from purchase. This guarantee doesn`t cover the price of set up, elimination or reinstallation, or damage ensuing from misuse, abuse, or damage from improper wiring or installation. This warranty doesn`t cowl incidental or consequential damages. LUTRON’S Liability ON ANY Declare FOR DAMAGES ARISING OUT OF OR IN CON­NEC­TION WITH THE MANUFACTURE, SALE, Set up, Delivery, OR USE OF THE UNIT SHALL Never EXCEED THE PUR­CHASE Price OF THE UNIT. This guarantee provides you specific legal rights, and you may have other rights which range from state to state. Some states don`t permit the exclusion or limitation of incidental or consequential damages, or limitation on how lengthy an implied guarantee could final, so the above limitations may not apply to you. Patents pending. Lutron, Maestro Wireless, and the Sunburst logo are registered trademarks and Radio Powr Savr is a trademark of Lutron Electronics Co., Inc. ANSI is a registered trademark of the American National Requirements Institute. IEC is a trademark of the International Electrotechnical Fee. Made and printed in the U.S.A. 25/09/09 P/N 041-172 Rev. A 8 ft (2.Four m) 18 x 18 ft (5.5 x 5.5 m) 13 ft (4.0 m) 9 ft (2.7 m) 20 x 20 ft (6.1 x 6.1 m) 14.5 ft (4.Four m) 10 ft (3.Zero m) 22 x 22 ft (6.7 x 6.7 m) 16 ft (4.9 m) 12 ft (3.7 m) 26 x 26 ft (7.9 x 7.9 m) 19 ft (5.8 m) Short-term Mounting Strategies 1.1 1.2 Insert the ceiling tile mounting wire by means of the 2 smaller holes in the mounting bracket and replace the mounting bracket. Mount Sensor to a ceiling tile by inserting the wire legs by means of the tile, ensuring the Sensor is flush to the tile. Word: Don`t twist wire legs collectively. 1.2 After the Sensor has been temporarily mounted, go away the Sensor in place on the tile and both take the tile down or remove an adjoining tile to achieve access to the legs of the mounting wire on the back of the tile. Low Exercise: This is essentially the most sensitive setting and will detect very slight motions. This is the really useful setting, as it would work properly for nearly all functions. It is good for spaces the place occupants will typically be seated for long durations of time. Twist the wire legs together tightly so the mounting bracket stays snug in opposition to the tile. This setting is slightly less sensitive than the Low Exercise setting and can be used for spaces that expertise normal activity. This is the least sensitive setting and can be used for spaces that can usually only expertise massive motions, resembling foot traffic. The Low Activity setting is the default and will perform greatest for most applications. Hardly ever, if the Sensor is positioned near exterior noise sources equivalent to heating vents, air conditioning vents, or light bulbs, it might turn the lights on without occupancy or keep the lights on too lengthy after vacancy. If this occurs, altering the sensitivity to Medium Exercise or High Activity should resolve the issue. Exchange the tile. Everlasting Solid Ceiling Mounting 2.1 2.2 2.3 Superior Set-Up Operation The advanced set-up is accessed by utilizing the buttons on the back of the Sensor. Drill two 3/16 in (4.6 mm) pilot holes for the provided screw anchors. Press the anchors into the holes and faucet flush with a hammer. To show the current setting, press and release the desired button. An LED will illuminate briefly, indicating the current setting. Place the flat aspect of the mounting bracket in opposition to the ceiling and install the two offered screws utilizing a hand screwdriver. To regulate a setting, press and hold the specified button till the LED corresponding to the present setting begins flashing rapidly, indicating the setting can now be adjusted. Every subsequent button press of less than 2 seconds will increment the mode to the subsequent obtainable setting. Urgent any of the opposite buttons will have no impact. To save the selected setting, press and hold the button till the LED turns on strong, indicating the saved setting. Through the adjustment process, if there isn`t a exercise for 30 seconds, the LEDs will turn off and no settings might be saved. Observe: Do not over-tighten. 2.Four Attach the Sensor to the mounting bracket by inserting and twisting in a clockwise direction until the Sensor locks into place. To take away the bracket from the ceiling, grasp the removal tab on the adhesive strip and pull the tab VERY SLOWLY straight throughout the ceiling, stretching the strip till the bracket releases from the ceiling. Discard the strip. Never pull the strip at an angle, as it might break or damage the ceiling floor. Notice: Do not pull at an angle. Lens Masking (Non-compulsory) At any time when doable, the Sensor needs to be installed in a location where it cannot easily see into areas outdoors the meant space, resembling hallways or adjacent rooms. If this case can`t be averted, parts of the lens could also be masked with the offered labels to dam the Sensor’s view of the undesired areas. It is recommended to remove the Sensor from the mounting bracket earlier than applying Advanced Set-Up (Non-obligatory) the masking labels. The Sensor options a number of superior set-up modes. For the vast majority of installations, the default settings will provide the best efficiency and you won`t must utilize the advanced set-up. The Occupancy version of the Sensor has three adjustable superior set-up modes: Timeout, Auto-On, and Sensitivity. The Vacancy-Only version has solely two modes (Auto-On not accessible). The default settings are listed under. The Sensor can be screwed onto the mounting bracket in several different orientations. Make certain to notice the Sensor’s orientation earlier than taking it down and replace the Sensor in the identical orientation to make sure the meant space will get blocked. Outer lens sections correspond to the detection areas furthest away from the Sensor, whereas internal sections correspond to areas nearer to the Sensor. Watch out when making use of the labels to avoid creating gaps between adjacent masked sections. The Sensor could detect motion by way of inadvertent gaps. All the time (Occupancy version solely) Timeout 30 min 15 min 5 min Auto-On At all times Low light Disable Activity Timeout 30 min 15 min 5 min Advanced Set-Up Modes Auto-On All the time Low gentle Disable Activity Exercise: Low Exercise Lens sections shown in white are masked with labels Timeout The Sensor will turn the lights off if no motion occurs throughout the timeout period. There are three obtainable timeout settings: 5, 15, and 30 minutes. Lens Mask Lens sections proven in gray haven`t been masked Auto-On The automated-on functionality of the Sensor can be adjusted to manage how the lights reply upon initial occupancy. There are three available settings: At all times, Low gentle, and Disable. Always: The lights will always turn on. Testing Sensor Protection With the Sensor mounted on the ceiling, press and launch the \"Test: Sensor\" button on the front of the device. The lens will glow briefly, indicating the take a look at mode has been entered. Word: There`s a heat-up interval of roughly forty seconds after the batteries are installed earlier than the take a look at mode will be activated. If the button is pressed during this time, the lens will flash repeatedly until the heat-up interval is full, after which the take a look at mode can be robotically entered. Confirm the coverage space by strolling by means of the house and observing the lens. The lens will glow solid every time motion is detected. If the lens stays off throughout movement, the Sensor can not detect movement at that location. Press and launch the \"Test: Sensor\" button again to exit the take a look at mode. If the button will not be pressed, the take a look at mode will robotically time out quarter-hour after being enabled, or 5 minutes after the last detected movement if the room is vacated. If the Sensor has significant hassle detecting motion in the course of the take a look at, it must be moved to a different location and retested. If the Sensor still has poor detection from the new location, confer with the Troubleshooting part. Non permanent Drop Ceiling Mounting Use this process if the Sensor will likely be mounted on a ceiling tile. The ceiling tile mounting wire is provided for each temporary and everlasting mounting of the Sensor to drop ceilings composed of multiple tiles. It is designed to allow momentary mounting, testing, and repositioning (if obligatory) of the Sensor without damaging a ceiling tile. As soon as the Sensor’s last place has been chosen, the mounting wire can be twisted to lock the Sensor in place completely. If the Sensor coverage and wireless communication tests have been successfully accomplished, use the mounting bracket as a template to mark the screw hole places with a pencil. Word: Pull very slowly. Max. Room Dimensions Radius of Coverage for Full Protection at Flooring In case you are uncertain about accurately positioning the Sensor, the following non permanent mounting and testing procedures are advisable to verify proper performance earlier than permanently putting in the Sensor. Sensor’s detection vary relies on the ceiling height, as shown in the desk below. Notice: Do not disassemble, crush, puncture, or incinerate the batteries. Don`t dispose of batteries in normal family waste. Please recycle, take to a correct battery disposal facility, or contact your local waste disposal supplier regarding native restrictions on the disposal or recycling of batteries. O NOT mount the Sensor inside 4 ft (1.2 m) of HVAC vents or gentle bulbs put in beneath the ceiling line. Warmer rooms could cut back the Sensor’s ability to detect occupants. Use solely excessive-high quality lithium batteries, size CR123, 3 V (ANSI-5018LC, IEC-CR17345). Do not use rechargeable batteries. Using improperly rated batteries may injury the Sensor. For questions regarding the installation or operation of this product, call the Lutron Technical Assist Middle. Please present exact model number when calling. U.S.A. and Canada (24 hrs / 7 days) Setting the Occupancy Light Level (occupancy model, dimming devices only) the Sensor to the mounting bracket by inserting and twisting in a clockwise 2.5 Attach path till the Sensor locks into place. Sensor coverage and wireless communication tests as described in 2.6 Carry out sections E. Testing Sensor Protection and F. Testing Wireless Communication. The Sensor needs to be installed in a location the place it has an excellent view of all elements of the room. The Sensor requires line of sight to operate properly. If you can not see the Sensor, it cannot see you. The Sensor can not see by glass objects reminiscent of patio or shower doorways. The vary and performance of the RF system is highly dependent on quite a lot of complicated factors reminiscent of: · Distance between system components · Geometry of the building structure · Development of partitions separating system parts · Electrical tools located near system parts Technical Help 2.2 Establish a location on the ceiling the place the Sensor could have a very good view of the room. 2.3 Take away the black \"wall side\" liner from the adhesive strip. The Sensor is designed for ceiling use solely. Don`t install on ceilings higher than 12 ft (3.7 m) or non-ceiling surfaces. Doing so may considerably inhibit the Sensor’s performance. 4. Do not paint Sensor. · · · · The \"Lights On\" and \"Lights Off\" buttons ought to now switch the lights in the room on and off, respectively, when pressed. Repeat the above procedure to set up the Sensor with any additional gadgets. The Sensor is meant for indoor use only. Operate between 32 °F and 104 °F (zero °C and forty °C). 1.1 several seconds. Sensor that has been arrange. After approximately 6 seconds, the lens will flash quickly a number of instances, indicating the sunshine degree has been saved. All Sensors set up with the Dimmer will now use the saved occupancy mild degree. 2. Clear Sensor with a comfortable damp cloth solely. Don`t use any chemical cleaners. Be aware: This tools has been examined and found to adjust to the limits for a class B digital machine, pursuant to part 15 of the FCC guidelines. These limits are designed to offer cheap safety against dangerous interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not put in and utilized in accordance with the directions, may trigger harmful interference to radio and television reception, which may be decided by turning the tools off and on. The user is inspired to try to appropriate the interference by a number of of the next measures: Reorient or relocate the receiving antenna. Improve the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit completely different from that to which the receiver is linked. Consult the vendor or an experienced radio/Tv technician for help. Caution: Modifications or modifications not expressly authorized by Lutron Electronics Co. may void the user’s authority to function this tools. This gadget complies with Half 15 of the FCC guidelines. This machine should accept any interference acquired, including interference that will cause undesired operation. Change 2.1 Set the Dimmer to the specified light degree for entering the room. 2.2 Save holding the \"Lights On\" button on the front of a Observe: For both Sensor version, the lights will also be manually turned off at any time by using the dimming or switching device straight. Necessary Notes or Add the Sensor to the Dimmer or Switch by urgent and holding the \"Lights Off\" button on the front of the Sensor for roughly 6 seconds until the lens flashes briefly. The lights within the room may also flash 3 instances, indicating the Sensor has been successfully added. The Dimmer or Swap will exit set-up mode robotically. The sensitivity of the Sensor could be adjusted based mostly on the expected degree of exercise within the room. There are three accessible exercise settings: Low Activity, Medium Activity, and High Activity. Everlasting Drop Ceiling Mounting Word: Leave the elimination tab exposed past the sting of the bracket so it may be accessed for elimination later. 6 seconds till all LEDs on the device begin flashing. Release the faucet button. Sensor is detecting movement in areas that aren`t desirable, akin to hallways or adjoining rooms, refer to section I. Lens Masking. If Sensor detection is satisfactory throughout this test, carry out the wireless communication test as described in part F. Testing Wireless Communication. Testing Wireless Communication This take a look at should be performed to confirm that the Sensor has been correctly arrange with the corresponding dimming or switching gadget and that there`s proper wireless communication from the chosen Sensor location. If the lights in the room will not be on, flip them ON manually on the dimming or switching system. Press and launch the \"Lights Off\" button on the entrance of the Sensor. The lights ought to flip OFF. Press and launch the \"Lights On\" button on the front of the Sensor. The lights should activate. If the lights do not respond accurately, discuss with the Troubleshooting section. Low gentle: The lights will only turn on automatically upon entry if there is not already adequate ambient light within the room. Hallway falls within Sensor’s protection area. Disable: This setting converts the Sensor to vacancy mode. The lights won`t routinely turn on but will nonetheless mechanically flip off after vacancy. The lights should be manually turned on by utilizing the associated dimming or switching gadget. Note: The 15-second vacancy grace interval is lively in this mode. Seek advice from the Sensor Operation part firstly of this doc for extra details. Troubleshooting Symptom Possible Causes Solution Lights do not activate when area is occupied. Sensor will not be appropriately added to dimming / switching gadget(s). Sensor’s Auto-On setting is set to \"Low light\" or \"Disable\". The lights were just lately turned off manually and the timeout has not yet expired. Sensor does not have full view of room. Sensor is exterior wireless vary of dimming/switching device. Confer with section B. Set-Up. Discuss with section H. Advanced Set-Up. Dimming/switching machine has been improperly wired. Light bulb(s) burned out. Breaker is off or tripped. Sensor’s timeout is simply too short for this application. Sensor does not have full view of room. Lens mask is improperly utilized. Sensor’s sensitivity is just too low. Sensor’s timeout has not but expired. An exterior noise source comparable to an HVAC vent is interfering. Seek advice from section A. Pre-Set up. Habits of lights does not match Sensor settings. Sensor coverage extends past room perimeter. The supposed setting was not saved. Multiple Sensors are added to a dimming/switching device and their settings do not match. Confer with section A. Pre-Installation. Discuss with section C. Sensor Placement or I. Lens Masking. Discuss with section H. Advanced Set-Up. Seek advice from section H. Superior Set-Up. Sensor lens does not glow in response to motion during Sensor coverage testing. Sensor can`t see movement due to obstruction. Room is just too huge or oddly formed. Move Sensor to a different location. Check with part C. Sensor Placement. A number of Sensors may be necessary for full room protection. Attempt shifting Sensor to a brand new location or reducing sensitivity. Refer to part C. Sensor Placement or H. Advanced Set-Up. Lights turn OFF while area is occupied. Lights keep ON after area is vacated. Lens does not cease glowing during Sensor coverage testing even when there isn`t a movement. Lights don`t respond correctly during wireless communication testing. Sensor lens flashes and lights don`t activate when area is occupied. Battery has been installed incorrectly. An external noise supply similar to an HVAC vent is interfering. Seek advice from part C. Sensor Placement. Check with part C. Sensor Placement or F. Testing Wireless Communication. Refer to section H. Advanced Set-Up. Confer with part C. Sensor Placement. Consult with part I. Lens Masking. Seek advice from section H. Superior Set-Up. Check with part H. Advanced Set-Up. Attempt moving Sensor to a new location or lowering sensitivity. Consult with section C. Sensor Placement or H. Superior Set-Up. Sensor is not appropriately added to dimming / switching gadget. Sensor is outside wireless range of dimming/switching system. Seek advice from part B. Set-Up. Transfer Sensor nearer to dimming/switching device and retry take a look at. Refer to part F. Testing Wireless Communication. Battery has been put in incorrectly. Dimming/switching machine has been improperly wired. Light bulb(s) burned out. Breaker is off or tripped. Battery is low. Check with part A. Pre-Installation. Remove sensor from check mode. Check with section E. Testing Sensor Protection.
2021-8-25 19:06:08 BY 游客   查看:25 次   以下共有回复:0 篇  
共0篇回复 每页10篇 页次:1/1
我要回复
回复内容
验 证 码
看不清?更换一张
匿名发表 
脚注信息
广东叶其芳健康咨询有限公司网站 Copyright(C)2009-2021